Main advantages:
1.Advanced internal resistance testing technology-Small signal pulse AC method;
2. Automatically allocate addresses and debug for "foolproof" functionality;
3. Multiple protections such as power isolation, optocoupler isolation, and fuses;
4. It has power anti reverse and anti short circuit protection functions;
5. Modular design, flexible configuration, and low solution cost.
1. Monitoring parameters: cell voltage, internal resistance, battery temperature;
2. Advanced internal resistance testing technology - small signal pulse AC method, with high acquisition accuracy;
3. High safety, multiple protections such as power isolation, optocoupler isolation, and fuse melting;
4. The detection module automatically assigns addresses, making debugging "foolproof" and highly practical;
5. It has power anti reverse and anti short circuit protection functions;
6.1 Module detection of 1 battery parameter;
7. Low power design, with an average power consumption of 0.1W and no impact on the battery.
detection channel | Number of batteries | 1 section | Each module detects 1 battery cell |
working conditions | power supply | 5~15V (6, 12V battery) | Battery self powered |
average power consumption | 0.1W | Low power design, does not affect the battery | |
cell voltage | input range | 5~15V (6, 12V battery) | 12V battery |
Collection accuracy | 0.2% FS | ||
Internal resistance detection | measurement range | 0~100mΩ | |
Collection accuracy | 2% FS | static testing | |
Temperature detection | measurement range | 0~80℃ | |
Collection accuracy | 1℃ | Related to sensors | |
external structure | L*W*H | 62*56*26mm | |
Materials | Flame retardant ABS plastic, flame retardant grade 94V-0 | ||